X

SNCR vs. SCR: Which NOx Reduction Technology Fits Your Plant?

H+H SCR Technology for lower NOx emissions
H+H SCR Technology for lower NOx emissions

SNCR vs. SCR

Selective Non-Catalytic Reduction (SNCR) and Selective Catalytic Reduction (SCR) are used to reduce nitrogen oxide (NOx) emissions in Waste-to-Energy and biomass plants. The two technologies differ in their reaction principle, technical requirements, and integration into existing plants.

SNCR vs. SCR: Technical Differences

SNCR reduces NOx without a catalyst. A reducing agent is injected into a suitable temperature zone of the combustion process, where the reduction reaction takes place.
SCR uses a catalyst. A reducing agent is introduced into the exhaust gas, and ammonia reacts with NOx at the catalyst surface to form nitrogen and water.

 

CriterionSNCRSCR
CatalystNoYes
ReactionTakes place within a suitable temperature zone of the combustion processTakes place at the catalyst surface
IntegrationUses suitable zones within the combustion processRequires a catalyst and associated equipment
Key parametersTemperature window, mixing, operating conditionsTemperature, catalyst sizing, pressure loss, exhaust-gas conditions
 
Which technology is suitable depends on the technical conditions and emission targets of the individual plant.

Options for an Existing SNCR System

1. Optimize the Existing SNCR System
The existing SNCR system should first be assessed for optimization potential.Relevant factors include process conditions, reducing-agent dosing and distribution, NOx performance, NH3 slip, and available operating margin.
If the required performance can be achieved through optimization, an additional reduction stage may not be necessary.

 

2. Retrofit an SCR System
An SCR retrofit adds a catalyst-based reduction stage to the existing plant.
Depending on the application, the system can include:
  • reducing-agent supply
  • dosing equipment
  • mixing and injection equipment
  • SCR reactor and catalyst
  • control system
  • sensors and analysis equipment
These components must be integrated into the existing exhaust-gas system.
 
3. Combine SNCR and SCR
An existing SNCR system does not necessarily have to be replaced when SCR is added.

In a combined SNCR-SCR system, the installed SNCR remains in operation while a downstream SCR stage provides additional catalyst-assisted NOx reduction. The existing SNCR equipment therefore remains part of the DeNOx system.

Technical Parameters for Retrofit Design

The retrofit design is based on the actual operating and installation conditions of the plant. Relevant parameters include:
  • Exhaust-gas temperature: Defines the available reaction and catalyst operating conditions.
  • Exhaust-gas volume flow: Influences reactor dimensions and system sizing.
  • Raw NOx concentration: Establishes the inlet conditions.
  • Required clean-gas target: Defines the required reduction performance.
  • NH3 slip: Must be evaluated together with NOx performance.
  • Allowable pressure loss: Limits the integration of additional equipment into the exhaust-gas path.
  • Available installation space: Defines the physical options for the retrofit.
  • Exhaust-gas composition: Influences the application-specific system design.
  • Operating profile: Defines the operating conditions for which the system must be designed.

SNCR and SCR Retrofit Engineering by H+H

H+H develops DeNOx retrofit concepts for existing Waste-to-Energy and biomass plants based on plant data, emission targets, and installation conditions.

The scope includes:

  • optimization of existing SNCR systems
  • SCR retrofit engineering and integration
  • combined SNCR-SCR systems

Which parameters influence an SCR retrofit?

Important engineering parameters include:

  • exhaust-gas temperature,
  • exhaust-gas volume flow,
  • raw NOx concentration,
  • required clean-gas target,
  • allowable pressure loss,
  • available installation space,
  • exhaust-gas composition,
  • operating profile.
Their interaction influences how the SCR system needs to be designed and integrated into the existing plant.

Is your existing SNCR system reaching its limits?

If your plant is approaching its NOx or NH3 slip targets, or if you are evaluating how to prepare the existing system for future requirements, the first step is to assess the plant as a whole.

H+H can evaluate the optimization potential of an existing SNCR installation and assess whether an SCR retrofit or combined SNCR-SCR solution is technically suitable for your Waste-to-Energy or biomass plant.

Talk to H+H about your retrofit requirements.
Kontakt