SNCR vs. SCR
SNCR vs. SCR: Technical Differences
| Criterion | SNCR | SCR |
|---|---|---|
| Catalyst | No | Yes |
| Reaction | Takes place within a suitable temperature zone of the combustion process | Takes place at the catalyst surface |
| Integration | Uses suitable zones within the combustion process | Requires a catalyst and associated equipment |
| Key parameters | Temperature window, mixing, operating conditions | Temperature, catalyst sizing, pressure loss, exhaust-gas conditions |
Options for an Existing SNCR System
1. Optimize the Existing SNCR System
The existing SNCR system should first be assessed for optimization potential.Relevant factors include process conditions, reducing-agent dosing and distribution, NOx performance, NH3 slip, and available operating margin.
If the required performance can be achieved through optimization, an additional reduction stage may not be necessary.
- reducing-agent supply
- dosing equipment
- mixing and injection equipment
- SCR reactor and catalyst
- control system
- sensors and analysis equipment
An existing SNCR system does not necessarily have to be replaced when SCR is added.
In a combined SNCR-SCR system, the installed SNCR remains in operation while a downstream SCR stage provides additional catalyst-assisted NOx reduction. The existing SNCR equipment therefore remains part of the DeNOx system.
Technical Parameters for Retrofit Design
- Exhaust-gas temperature: Defines the available reaction and catalyst operating conditions.
- Exhaust-gas volume flow: Influences reactor dimensions and system sizing.
- Raw NOx concentration: Establishes the inlet conditions.
- Required clean-gas target: Defines the required reduction performance.
- NH3 slip: Must be evaluated together with NOx performance.
- Allowable pressure loss: Limits the integration of additional equipment into the exhaust-gas path.
- Available installation space: Defines the physical options for the retrofit.
- Exhaust-gas composition: Influences the application-specific system design.
- Operating profile: Defines the operating conditions for which the system must be designed.
SNCR and SCR Retrofit Engineering by H+H
H+H develops DeNOx retrofit concepts for existing Waste-to-Energy and biomass plants based on plant data, emission targets, and installation conditions.
The scope includes:
- optimization of existing SNCR systems
- SCR retrofit engineering and integration
- combined SNCR-SCR systems
Which parameters influence an SCR retrofit?
Important engineering parameters include:
- exhaust-gas temperature,
- exhaust-gas volume flow,
- raw NOx concentration,
- required clean-gas target,
- allowable pressure loss,
- available installation space,
- exhaust-gas composition,
- operating profile.
Is your existing SNCR system reaching its limits?
If your plant is approaching its NOx or NH3 slip targets, or if you are evaluating how to prepare the existing system for future requirements, the first step is to assess the plant as a whole.
H+H can evaluate the optimization potential of an existing SNCR installation and assess whether an SCR retrofit or combined SNCR-SCR solution is technically suitable for your Waste-to-Energy or biomass plant.